VEVKbSHp 1 kV; 6 kV, VVKbSHp 1 kV (ВЭВКбШп 1 кВ; 6 кВ; ВВКбШп 1 кВ) These cables are intended for transmission and power distribution in stationary installation at rated voltage of 1.0 kV and 6 kV, AC 50Hz laid in dry land at ambient temperature from -40 °C to +50 °C and (98±2)% relative air humidity at (35±2)°C; laid in water, above ground and waterlogged land — at ambient temperature from +2 °C to +35 °C. Cables are not to be exposed to direct sun.
KPEVKbSHp (КПЭВКбШп) 1 kV and 6 kV Cables are intended for transmission and power distribution in stationary installation at rated voltage of 1.0 kV and 6 kV, AC 50Hz frequency laid in dry land and open-air at ambient temperature from -50°C to +50 °C and 100% relative air humidity at (35±2)°C; laid in water and salt water — at ambient temperature from +2 °C to +35 °C. Cables are not exposed to direct sun. The proposed construction of cable have longitudinal and radial hermiticity achieved by electroconductive water-blocking tapes and threads. Strength of cable achieved by round-wire armour.
Power flexible cables for excavatorsKGEV, KGEV-HL (КГЭB, КГЭB-ХЛ)6 kV Cables are designated to connect excavators and movable devices or electric equipment to power systems with an insulated neutral at AC rated voltage of rated frequency 50 Hz:for main conductors — 6 kVauxiliary conductors — 380 V in systems equipped with automatic power shutdown in case of a single-phase short-circuit at 98% relative air humidity at (35±2)°C and at ambient temperature:from -40 °C to +50 °C (KGEV)from -50 °C to +50 °C (KGEV-HL)
SIP-4, SIPn-4, SIP-4…g (СИП-4, СИПн-4, СИП-4…г) 0.6/1 kV These wires are used for long-distance electric power lines for the rated voltage of 0.6/1 kV to the input and for the laying on the walls of buildings and engineering structures, at a rated frequency of 50 Hz. Climate class (NF), location categories 1, 2 and 3. Wire SIP-4 (AsXS): self-supporting wire with a light-stabilized XLPE insulation. Wire SIPn-4 (AsXSn): self-supporting and flame-retardant wire with a light-stabilized XLPE insulation. This wire have flame-retarding ability when laid in bundles. Wire SIP-4…g: self-supporting wire with a light-stabilized XLPE insulation with sealed conductor, light-stabilized XLPE insulation. Ordering designation of cable: SIPn-4 2×16 — 0.6/1.0. Conformity the foreign-made analogues: AsXS, AAsXSn, AsXSn (Poland)
PvP2g, PvPu2g, APvP2g, APvPu2g (ПвП2г, ПвПу2г, АПвП2г, АПвПу2г) Single-core power cables: АPvBaP2g, PvBaP2g, APvKaP2g, PvKaP2g (АПвБаП2г, ПвБаП2г, АПвКаП2г, ПвКаП2г) Three-core power cables: АPvBP2g, PvBP2g, APvKP2g, PvKP2g (АПвБП2г, ПвБП2г, АПвКП2г, ПвКП2г) 3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV These cables are intended for laying in premises, in ducts, channels and places where mechanical impacts on cables, including stretching forces, might be possible. Also these cables can be used for installation on lines of complicated configuration. Cables with screen sealing are used undergrounds with increased moisture and in partially flooded premises. Ordering designation of cable: PvPu2g — 6/10 kV 1×35/16. Conformity the foreign-made analogues: N2XS(FL)2Y (2XS(FL)2Y), NА2XSF(L)2Y, NА2XS(FL)2Y, VDE 0276-620:1996 (HD 620 S1, 5С, 6С)
Three-core power cables with XLPE insulation armoured with galvanized steel tape or steel wire and polyethylene oversheath PvBP, PbKP, APvBP, APvKP (ПвБП, ПбКП, АПвБП, АПвКП) 3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV These cables are intended for laying in premises, in ducts, channels, dry soils and places where mechanical impacts on cables, including stretching forces, might be possible. Also these cables can be used for installation on lines of complicated configuration. The cables of PvKP, APvKP types are specially intended for laying in ordinary soils (trenches), as well as in highly corrosive soils. Ordering designation of cable: PvBP – 6/10 kV 3×95/25. Conformity the foreign-made analogues: N2XSEBY, VDE 0276-620:1996 (HD 620 S1, 5С, 6С)
Power cables with XLPE insulation, longitudinal screen sealing and polyethylene or reinforced polyethylene oversheath, including armoured: PvPg, PvPug, APvPg, APvPug (ПвПг, ПвПуг, АПвПг, АПвПуг) Single-core power cables: APvBaPg, PvBaPg, APvKaPg, PvKaPg (АПвБаПг, ПвБаПг, АПвКаПг, ПвКaПг) Three-core power cables: APvBPg, PvBPg, APvKPg, PvKPg (АПвБПг, ПвБПг, АПвКПг, ПвКПг) 3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV These cables are intended for laying in premises, in ducts, channels and places where mechanical impacts on cables, including stretching forces, might be possible. Also these cables can be used for installation on lines of complicated configuration. Cables with screen sealing are used undergrounds with increased moisture and in partially flooded premises. Ordering designation of cable: APvBPg – 12/20 kV 3×120/16. Conformity the foreign-made analogues: N2XS(F)2Y (2XS(F)2Y); NА2XS(F)2Y (А2XS(F)2Y), VDE 0276-620:1996 (HD 620 S1, 5С, 6С)
Berdyansk Cable Plant supplies products to customers from a wide range of sectors of the economy. An individual approach to each client, flexible pricing policy, fulfillment of contractual obligations with a high degree of reliability are the main principles of our work.