Self-supporting and flame-retardant wires with a light-stabilized XLPE insulation
0.6/1 kV

Self-supporting and flame-retardant wires with a light-stabilized XLPE insulation
0.6/1 kV

TU U 27.3-31850229-023:2007
IEC 4743:2007

 

Application

SIP-4, SIPn-4, SIP-4…g (-4, -4, -4…)

0.6/1 kV

These wires are used for long-distance electric power lines for the rated voltage of 0.6/1 kV to the input and for the laying on the walls of buildings and engineering structures, at a rated frequency of 50 Hz.

Climate class (NF), location categories 1, 2 and 3.

Wire SIP-4 (AsXS): self-supporting wire with a light-stabilized XLPE insulation.

Wire SIPn-4 (AsXSn): self-supporting and flame-retardant wire with a light-stabilized XLPE insulation. This wire have flame-retarding ability when laid in bundles.

Wire SIP-4…g: self-supporting wire with a light-stabilized XLPE insulation with sealed conductor, light-stabilized XLPE insulation.

Ordering designation of cable: SIPn-4 2×16–0.6/1.0.

Conformity the foreign-made analogues:
AsXS, AAsXSn, AsXSn (Poland)

 

Construction

Conductor
Aluminum multicore compacted conductor
Wires with sealed conductor are designated as SIP-4 4x16g
Wires with sealed conductor are contain a water-blocking material or materials.

Insulation
Laid-on by extrusion from cross-linked polyethylene (XLPE).

Technical characteristics

Rated voltage 0.6/1 kV
Number of main conductors 1, 2, 3, 4
Nominal main conductor cross-section 10 – 240 mm
Nominal auxiliary conductor cross-section for exterior lighting 16 mm; 25 mm
Ambient temperature during operation from -60 °C up to +50 °C
Wires are resistant to the effects of solar irradiation
Sealed conductors of wires are resistant to longitudinal propagation of water
Minimal temperature of wire laying without pre-heating -20 °C
Maximum permissible temperature for the conductors heating:
  • at normal operation mode
  • in short circuit mode



+90 °C
+250 °C

Minimum allowed radius of bending during wire laying, no less: 10 outer diameters of wire
Guarantee period 3 years
Service life 40 years


Technical Data (reference values)

Wire
Self-supporting and flame-retardant wire with a light-stabilized XLPE insulation
SIP-4 (AsXS), SIPn-4 (AsXSn) for nominal voltage up to 0.6/1 kV
Number and nominal cross-section of conductors, mm Nominal overall diameter, mm Weight of 1km of wire, kg
2×10 13.00 95
2×16 15.00 137
2×25 18.00 195
2×35 20.00 256
2×50 23.00 395
2×70 27.00 491
2×95 31.00 649
2×120 34.00 813
3×10 14.00 143
3×16 16.00 197
3×25 19.00 292
3×35 22.00 383
3×50 25.00 533
3×70 29.00 737
3×95 34.00 973
3×120 36.00 1219
4×10 15.00 184
4×16 18.00 262
4×25 23.00 389
4×35 24.00 511
4×50 29.00 711
4×70 32.00 983
4×95 38.00 1298
4×120 41.00 1626
4×150 45.00 1978
2×25+1×16 19.00 260
2×25+2×16 20.60 326
235+116 19.20 321
235+125 20.00 353
235+216 21.40 387
235+225 25.00 450
250+116 24.00 421
250+125 28.00 453
250+216 25.60 487
250+225 28.70 511
270+116 27.00 557
270+125 27.20 589
270+216 27.20 623
270+225 27.20 686
295+116 31.00 714
295+125 31.00 746
295+216 31.00 780
295+225 31.00 843
2120+116 34.00 878
2120+125 34.00 910
2120+216 34.00 943
2120+225 34.00 1007
3×25+1×16 22.30 358
3×25+2×16 26.40 423
335+116 22.40 449
335+125 26.00 481
335+216 26.40 515
335+225 28.00 578
350+116 26.40 515
350+125 29.00 631
350+216 30.20 664
350+225 31.40 728
370+116 30.00 803
370+125 31.10 835
370+216 33.40 868
370+225 35.00 932
395+116 35.00 1039
395+125 35.00 1071
395+216 39.00 1104
395+225 40.00 1168
3120+116 36.00 1285
3120+125 36.80 1317
3120+216 41.00 1350
3120+225 43.00 1414
4×25+1×16 24.80 455
4×25+2×16 27.00 520
435+116 26.40 577
435+125 28.00 609
435+216 29.00 642
435+225 29.00 708
450+116 29.80 777
450+125 31.00 808
450+216 31.40 842
450+225 31.40 906
470+116 34.00 1049
470+125 35.00 1080
470+216 36.00 1114
470+225 36.00 1178
495+116 39.00 1369
495+125 40.00 1395
495+216 46.00 1429
495+225 46.00 1492
4120+116 41.00 1691
4120+125 42.20 1723
4120+125 44.00 1757
4120+225 44.00 1820

Permissible current loads calculated for the ambient temperature +25 C, wind speed 6 m/s and solar radiation intensity 1000 Vt/m, and permissible short-circuit currents for these wires are described in cross-section «Reference data».

Wires are bending – resistant during installation. Suspension of wires in overhead power lines must meet the requirements of Electrical Installation Regulations.

Manufactured wire lengths may be agreed with the customer request. Transportation and storage of wire must be in accordance with GOST 18690.

The manufacturer can ensure compliance of wire quality with requirements of DSTU 4743 and current technical specification, provided all terms of transportation, storage, installation and use have been observed.

On customers request other marking of wire is allowed.

Wires are delivered on drums.

All products are certified.

©