Power cables

Power cables with XLPE insulation and polyethylene or polyethylene reinforced oversheath

Power cables with XLPE insulation and polyethylene or polyethylene reinforced oversheath:

PvP, PvP, PvPu, PvPu (, , , )

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV


These cables are intended for transmission and power distribution in stationary installations of medium voltage, AC 50 or 60 Hz, and for networks with grounded and insulated neutral categories A, B and C, according to international standard IEC 60183 DSTU.

When the cable is installed outdoors without protection from solar radiation, including installation in cable constructions, it is necessary to provide additional measures of fire-fighting protection.

For installation on routes with unlimited difference of elevation.

Cables with reinforced oversheath are specially intended for laying at the complicated sections of the lines in accordance with the ETU.

Climate class (N) and (NF), location categories 1 and 2.

Ordering designation of cable: APvP – 6/10 kV 1×50/16.

Conformity the foreign-made analogues:
N2XS2Y, N2XS2Y (2XS2Y); NA2XS2Y, NA2XS2Y (A2XS2Y) VDE 0276-620:1996 (HD 620 S1, 5, 6)

Single-core power cables with XLPE insulation, armoured by aluminum tape or aluminum wire in polyethylene oversheath

Single-core power cables with XLPE insulation, armoured by aluminum tape or aluminum wire in polyethylene oversheath:

PvBaP, PbKaP, APvBaP, APvKaP (, , , )

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV

These cables are intended for laying in premises, in ducts, channels, dry soils and places where mechanical impacts on cables, including stretching forces, might be possible. Also these cables can be used for installation on lines of complicated configuration.

The cables of PvKaP, APvKaP types are specially intended for laying in ordinary soils (trenches), as well as in highly corrosive soils.

Ordering designation of cable: APvKaP – 6/10 kV 1×300/16.


Power cables with XLPE insulation and PVC oversheath, including armoured

Power cables with XLPE insulation and PVC oversheath, including armoured: PvV, APvV (, )

Single-core power cables: PvBaV, APvBaV, PvKaV, APvKaV (, , , )

Three-core power cables: APvBV, PvBV, APvKV, PvKV (, , , )

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV

These cables are intended for transmission and power distribution in stationary installations of medium voltage and for networks with grounded and sulated neutral.

These cables are intended for stationary laying in premises, in cable constructions. It is allowed to install cable in dry soils.

For installation on routes with unlimited difference of elevation.

Cables are flame retardant with a single laying.

Ordering designation of cable: APvV – 8.7/15 kV 1×500/35.

Power cables with XLPE insulation and PVC flame-retardant oversheath, including armoured

Power cables with XLPE insulation and PVC flame-retardant oversheath, including armoured: PvVng, APvVng (, )

Single-core power cables: PvBaVng, APvBaVng, PvKaVng, APvKaVng (, , , )

Three-core power cables: APvBVng, PvBVng, APvKVng, PvKVng (, , , )

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV

These cables are intended for transmission and power distribution in stationary installations of medium voltage and for networks with grounded and insulated neutral.

These cables are intended for stationary laying in premises, in cable constructions. Cables are designated for laying in workings that require fire safety when laid in bundles.

Ordering designation of cable: PvBVng – 6/10 kV 3×240/25.

Conformity the foreign-made analogues:
N2XSY, N2XSEY (2XSY, 2XSY), NA2XSY, NA2XSEY (A2XSY, A2XSY), NA2S2Y, N2S2Y, VDE 0276-620:1996 (HD 620 S1, 5, 6)


Power cables with XLPE insulation and PVC flame-retardant oversheath with low smoke and gas emission, including armoured

Power cables with XLPE insulation and PVC flame-retardant oversheath with low smoke and gas emission, including armoured: PvVngLS, PvVngLS (LS, LS)

Single-core cables: PvBaVngLS, PvBaVngLS, PvKaVngLS, PvKaVngLS (LS, LS, LS, LS)

Three-core cables: PvBVngLS, PvBVngLS, PvKVngLS, PvKVngLS (LS, LS, LS, LS)

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV

These cables are intended for transmission and power distribution in stationary installations of medium voltage and for networks with grounded and insulated neutral.

These cables are intended for stationary laying in premises, in cable constructions. Cables are designated for stationary installation in bundles laying in workings.

Ordering designation of cable: PvBVngLS – 6/10 kV 3×185/35.

Conformity the foreign-made analogues:
N2XSY, N2XSEY (2XSY, 2XSY), NA2XSY, NA2XSEY (A2XSY, A2XSY), NA2S2Y, N2S2Y, VDE 0276-620:1996 (HD 620 S1, 5, 6)

Power cables with XLPE insulation, longitudinal screen sealing and polyethylene or reinforced polyethylene oversheath, including armoured

Power cables with XLPE insulation, longitudinal screen sealing and polyethylene or reinforced polyethylene oversheath, including armoured: PvPg, PvPug, APvPg, APvPug (, , , )

Single-core power cables: APvBaPg, PvBaPg, APvKaPg, PvKaPg (, , , a)

Three-core power cables: APvBPg, PvBPg, APvKPg, PvKPg (, , , )

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV

These cables are intended for laying in premises, in ducts, channels and places where mechanical impacts on cables, including stretching forces, might be possible. Also these cables can be used for installation on lines of complicated configuration.

Cables with screen sealing are used undergrounds with increased moisture and in partially flooded premises.

Ordering designation of cable: APvBPg – 12/20 kV 3×120/16.

Conformity the foreign-made analogues:
N2XS(F)2Y (2XS(F)2Y); N2XS(F)2Y (2XS(F)2Y), VDE 0276-620:1996 (HD 620 S1, 5, 6)


Three-core power cables with XLPE insulation armoured with galvanized steel tape or steel wire and polyethylene oversheath

Three-core power cables with XLPE insulation armoured with galvanized steel tape or steel wire and polyethylene oversheath

PvBP, PbKP, APvBP, APvKP (, , , )

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV

These cables are intended for laying in premises, in ducts, channels, dry soils and places where mechanical impacts on cables, including stretching forces, might be possible. Also these cables can be used for installation on lines of complicated configuration.

The cables of PvKP, APvKP types are specially intended for laying in ordinary soils (trenches), as well as in highly corrosive soils.

Ordering designation of cable: PvBP – 6/10 kV 3×95/25.

Conformity the foreign-made analogues:
N2XSEBY, VDE 0276-620:1996 (HD 620 S1, 5, 6)

Power cables with XLPE insulation, longitudinal and transverse sealing and polyethylene or polyethylene reinforced oversheath, including armoured

PvP2g, PvPu2g, APvP2g, APvPu2g (2, 2, 2, 2)

Single-core power cables: PvBaP2g, PvBaP2g, APvKaP2g, PvKaP2g (2, 2, 2, 2)

Three-core power cables: PvBP2g, PvBP2g, APvKP2g, PvKP2g (2, 2, 2, 2)

3.6/6; 6/10; 8.7/15; 12/20; 18/30 kV

These cables are intended for laying in premises, in ducts, channels and places where mechanical impacts on cables, including stretching forces, might be possible. Also these cables can be used for installation on lines of complicated configuration.

Cables with screen sealing are used undergrounds with increased moisture and in partially flooded premises.

Ordering designation of cable: PvPu2g – 6/10 kV 1×35/16.

Conformity the foreign-made analogues:
N2XS(FL)2Y (2XS(FL)2Y), N2XSF(L)2Y, N2XS(FL)2Y, VDE 0276-620:1996 (HD 620 S1, 5, 6)



©