+380 6153 22022
  +380 6153 20000
Power cables

Power cables

Copper power cables with PVC insulation 0.66kV
VVG, VVGz (, ) 0.66 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.

VVGz cables are designated for fixed connection to electric devices at nominal AC voltage up to 0.66 kV at frequency 50 Hz. Cables are used for connection to devices requiring input sealing.

Aluminum power cables with PVC insulation 0.66 kV

AVVG, AVVGz (A, A) 0.66 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 1 kV and 6 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.

AVVGz cables are designated for fixed connection to electric devices at nominal AC voltage up to 0.66 kV at frequency 50 Hz. Cables are used for connection to devices requiring input sealing.


Armoured copper power cables with PVC insulation 0.66 kV

VBbSHv () 0.66 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.

Armoured aluminum power cables with PVC insulation 0.66 kV

AVBbSHv (A) 0.66 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.


Copper power cables with PVC insulation 1 kV; 6 kV

VVG, VVGz (, ) 1 kV; 6 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 1 kV and 6 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.

VVGz cables are designated for fixed connection to electric devices at nominal AC voltage up to 0.66 kV at frequency 50 Hz. Cables are used for connection to devices requiring input sealing.

Aluminum power cables with PVC insulation 1 kV; 6 kV

AVVG, AVVGz (A, A) 1 kV; 6 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 1 kV and 6 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.

AVVGz cables are designated for fixed connection to electric devices at nominal AC voltage up to 0.66 kV at frequency 50 Hz. Cables are used for connection to devices requiring input sealing.


Armoured copper power cables with PVC insulation 1 kV; 6 kV

VBbSHv () 1 kV; 6 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 1 kV and 6 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.

Armoured aluminum power cables with PVC insulation 1 kV, 6 kV

AVBbSHv (A) 1 kV; 6 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 1 kV and 6 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.


Five-core power cables with PVC insulation

VVG, VVGz, VBbSHv, AVVG, AVVGz; AVBbSHv, VVGng, VVGzng, VBbSHvng, AVVGzng, AVBbSHvng
(, , , , , , , , , , )
0.66 kV and 1 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 1 kV and 6 kV at frequency 50 Hz at ambient temperature from -40 C to +50 C and relative humidity up to 98% at temperature up to 35 C.

Armoured power cables for horizontal, slopping and vertical cable installation, 6 kV

VEVBbSHv, VEVKbSHv, AVEVSHv, AVEVBbSHvng, AVEVKbSHvng, AVEVSHvng (, , , , B, )

6 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 6 kV, frequency 50 Hz at ambient temperature from -30 C to +50 C and relative humidity up to 98% at temperature up to 35 C.

VEVBbSHv, AVEVSHv cables are designated for laying in horizontal and vertical mining workings and outdoor laying in conditions of hardwiring and by wells on the suspension to the hawser.

VEVKbSHv, VEVBbSHv, AVEVSHv cables are flame retardant with a single laying in vertical mining workings not gaseous-and-dusty mines.

AVEVBbSHvng, AVEVKbSHvng, AVEVSHvng cables are designated for workings requiring fire safe bundled laying, high fire security, low level of smoke and toxic emission from burning.


Power cables with flame-retardant PVC oversheath, 0.66 kV; 1 kV; 6 kV

VVGng, VVGzng, VBbSHvng, AVVGng, AVVGzng, AVBbSHvng
(, , , , , )

0.66 kV; 1 kV; 6 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV, 1 kV and 6 kV at frequency 50 Hz.

Cables are designated for workings requiring fire safe bundled laying, high fire security, low level of smoke and toxic emission from burning (in tube and power stations, channels, skyscrapers, industrial and public buildings).

Cables are intended for laying where required special fire-prevention measures for the protection of people and material values.

Cables can be used in DC networks. Nominal DC voltage is 2.4 times more than nominal AC voltage.

Cables are designated at ambient temperature from -40 C up to +50 C and relative humidity up to (98±2)% at temperature at temperature to 35 C.

Power cables with low smoke and gas emission PVC oversheath

VVGngLS, VVGzngLS, VBbSHvngLS, AVVGngLS, AVVGzngLS, AVBbSHvngLS
(LS, LS, LS, LS, LS, LS)
0.66 kV; 1 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV, 1 kV and 6 kV at frequency 50 Hz.

Cables are designated for workings requiring fire safe bundled laying, high fire security, low level of smoke and toxic emission from burning (in tube and power stations, channels, skyscrapers, industrial and public buildings).

Cables are intended for laying where required special fire-prevention measures for the protection of people and material values.

Cables can be used in DC networks. Nominal DC voltage is 2.4 times more than nominal AC voltage.

Cables are designated at ambient temperature from -30 C up to +50 C and relative humidity up to (98±2)% at temperature to 35 C.


Power cables with low level of smoke, halogen-free PVC oversheath

VVGngLSHF, VVGzngLSHF, VBbSHvngLSHF, AVVGngLSHF, AVVGzngLSHF, AVBbSHvngLSHF
(LSHF, LSHF, LSHF, LSHF, LSHF, LSHF)
0.66 kV; 1 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV, 1 kV and 6 kV at frequency 50 Hz.

Cables are designated for workings requiring fire safe bundled laying, high fire security, low level of smoke and toxic emission from burning (in tube and power stations, channels, skyscrapers, industrial and public buildings).

Cables are intended for laying where required special fire-prevention measures for the protection of people and material values.

Cables can be used in DC networks. Nominal DC voltage is 2.4 times more than nominal AC voltage.

Cables are designated at ambient temperature from -30 C up to +50 C and relative humidity up to (98±2)% at temperature at temperature to 35 C.

Power cables with XLPE oversheath

PvVG, APvVG, PvBbSHv, APvBbSHv
(B, , , )
0.66 kV, 1 kV

Cables are designated for power supply and distribution in fixed installations with rated AC voltage 0.66 kV, 1 kV at frequency 50 Hz at ambient temperature from -50 C to +50 C and relative humidity up to 98% at temperature up to 35 C, cables are intended for laying in outdoors including.



©
2003–2021 CJSC Production Association Berdyansk Cable Plant
71101, Ukraine, Zaporozhye region,
Berdyansk, Promyshlennaya St., 2b
Phone: +380-6153-20000 (reception)
Made by 