Power flexible cables for excavators

Power flexible cables for excavators

TU U 31.3-31850229-026:2009
IEC 60502-2 (1998-03)

 

Application

KGEV, KGEV-HL (B, B-) 6 kV

Cables are designated to connect excavators and movable devices or electric equipment to power systems with an insulated neutral at AC rated voltage of rated frequency 50 Hz for main conductors – 6 kV, auxiliary conductors – 380 V in systems equipped with automatic power shutdown in case of a single-phase short-circuit at 98% relative air humidity at (35±2)C and at ambient temperature from -40 C to +50 C (KGEV); and at ambient temperature from -50 C to +50 C (KGEV-HL).

 

Construction

Conductors
Multicore copper round stranded conductors (equal to or more than class 5 in accordance with GOST 22483-77).

Screen over main conductor
Semiconducting screen from electroconductive PVC compound.

Insulation of main and auxiliary conductors
Thermoplastic compound from polyvinylchloride resin.

Screen over insulation of main conductors
Semiconducting screen from electroconductive PVC compound.

Earth conductor
Earth conductor is uninsulated or expansible electroconductive PVC compound screen is laying-on over earth conductor.

Oversheath
Polyvinylchloride (PVC) compound.

Technical characteristics

At customer request is allowed manufacture of cables with another number of main conductors and another cross-section of auxiliary conductors and earth conductor.

Conductors resistance of main and auxiliary conductors calculated for 1 km at 20 C complies with GOST 22483-77.

Insulation resistance calculated for 1 km at 20 C is at least:

  • for main conductors:
    • at acceptance and delivery – 50 MOhm;
    • for operational and storage period – 0.5 MOhm;
  • for auxiliary conductors:
    • at acceptance and delivery – min. 10 MOhm;
    • for operational and storage period – 0.05 MOhm.

Main conductors endure test rated voltage of 15 kV AC, 50 Hz rated frequency for 5 min.

Auxiliary conductors endure test rated voltage of 2 kV AC, 50 Hz rated frequency for 5 min.

Electric potential at emerging of partial discharge of main screened conductors not less 9 kV, electric potential at cut off of partial discharge – not less 6 kV.

Cables resist alternation bending around rollers to the angle of π radian with stretching of 196 H.

Diameter of rollers and number of alternating bending:

Nominal conductor cross-section, mm Nominal diameter of rollers, mm Number of alternating bending
10 – 50 400 40000
70 – 150 600 30000

Allowed deviation of roller diameter ±10%.

Cables are resistant to influence of ambient mechanical factors according to group of exploitation conditions of M4 in accordance with GOST 17516.1.

Coefficient of reduction flexibility of cable at changing temperature from –50 C up to +25 C should be no more than 10.

Cables are resistant to sun radiation.

Cables are flame retardant with a single laying.

Manufactured cable length: min. 200 m.

Durable permissible operating temperature for conductors of KGEV, KGEV-HL cables – max. 75 C.

Minimum permissible bending radius of the cable at installation and routing must equal to min. 6 outer diameters of the cable, at wire rolling and winding - min. 10 outer diameters of the cable.

Maximum stretching of the cable must not exceed 24.5 H , cable stress at wire rolling and winding – max. 10 H per mm of compound cross-section area of conductors.

Cable must not be exposed to crushing load and impact load.

Cable ends must be sealed off.

Cable must not be used in case its oversheath is damaged.

Earth conductor must be connected to earth lead whenever cable is in operation.

Auxiliary conductor must be connected to monitoring equipment of earth conductor integrity providing for signalization and automatic shutdown of the cable line.

Excavator feeder at substations and terminals must be connected to the equipment that provides automatic shutdown of the cable line in case of a single-phase short-circuit. Shutdown time must not exceed 0.2 sec., and max. 0.5 sec. - with backup protection.

Cable without an auxiliary conductor must be checked for integrity of earth conductor.

Cable must not be used in case its earth or auxiliary conductors are damaged.

Guarantee period: 1 year from the commissioning date.

The manufacturer can ensure compliance of cable quality with requirements of current technical specification, provided all terms of transportation, storage, installation and use have been observed.

Service life: min. 3 years, if operating on mechanisms equipped with swinging paying out drums – min. 5 years, provided operation directions have been observed.

All products are certified.


Durable permissible current load at rated environmental temperature 25 C and operating temperature for conductors 75 C:

Nominal main conductor cross-section, mm Admissible continuous current, A
10 83
16 106
25 143
35 172
50 215
70 263
95 316
120 368
150 414

Technical Data (reference values)
KGEV
Number and nominal conductors cross-section, mm Rated voltage, kV Nominal overall diameter, mm Nominal overall diameter, mm
310+16.0 6.0 41.8 2262
316+16.0 6.0 43.7 2579
316+110 6.0 43.7 2603
325+110 6.0 47.8 3193
325+116 6.0 47.8 3236
335+110 6.0 49.6 3620
335+116 6.0 49.6 3663
350+116 6.0 55.6 4606
350+125 6.0 55.6 4659
370+116 6.0 62.8 6046
370+125 6.0 62.8 6100
395+125 6.0 66.3 7152
395+135 6.0 66.3 7228
3120+135 6.0 72.4 8564
3120+150 6.0 72.4 8637
3150+150 6.0 74.9 9728
3150+170 6.0 74.9 9878
310+16.0+14.0 6.0 41.8 2290
310+16.0+16.0 6.0 41.8 2305
316+16.0+16.0 6.0 43.7 2622
316+110+16.0 6.0 43.7 2645
325+110+16.0 6.0 47.8 3235
325+116+110 6.0 47.8 3303
335+110+16.0 6.0 49.6 3663
335+116+110 6.0 49.6 3730
350+116+110 6.0 55.6 4673
350+125+116 6.0 55.6 4769
370+116+110 6.0 62.8 6113
370+125+116 6.0 62.8 6209
395+125+110 6.0 66.3 7219
395+135+116 6.0 66.3 7337
3120+135+110 6.0 72.4 8631
3120+150+116 6.0 72.4 8747
3150+150+110 6.0 74.9 9795
3150+170+116 6.0 74.9 9988
KGEV-HL
Number and nominal conductors cross-section, mm Rated voltage, kV Nominal overall diameter, mm Nominal overall diameter, mm
310+16.0 6.0 41.8 2093
316+16.0 6.0 43.7 2397
316+110 6.0 43.7 2423
325+110 6.0 47.8 2984
325+116 6.0 47.8 3029
335+110 6.0 49.6 3398
335+116 6.0 49.6 3443
350+116 6.0 55.6 4339
350+125 6.0 55.6 4397
370+116 6.0 62.8 5691
370+125 6.0 62.8 5750
395+125 6.0 66.3 6790
395+135 6.0 66.3 6846
3120+135 6.0 72.4 8123
3120+150 6.0 72.4 8205
3150+150 6.0 74.9 9271
3150+170 6.0 74.9 9425
310+16.0+14.0 6.0 41.8 2126
310+16.0+16.0 6.0 41.8 2141
316+16.0+16.0 6.0 43.7 2445
316+110+16.0 6.0 43.7 2472
325+110+16.0 6.0 47.8 3033
325+116+110 6.0 47.8 3108
335+110+16.0 6.0 49.6 3447
335+116+110 6.0 49.6 3521
350+116+110 6.0 55.6 4418
350+125+116 6.0 55.6 4521
370+116+110 6.0 62.8 5770
370+125+116 6.0 62.8 5874
395+125+110 6.0 66.3 3882
395+135+116 6.0 66.3 7005
3120+135+110 6.0 72.4 8202
3120+150+116 6.0 72.4 8329
3150+150+110 6.0 74.9 9350
3150+170+116 6.0 74.9 9550
©