GOST 7399-97
IEC 60502-1 (1998-11)

 

Application

PVS, SHVVP (, ) 380 V

Connecting wires and cores are designated for connecting with electric appliances and white goods for power network at nominal AC voltage up to 380 V of 380/660 V systems at ambient temperature from -40 C to +40 C.

PVS wires are designated for connection for white goods, electric soldering irons, lamps, etc. Wires are also designated for manufacturing of cord extension sets.

SHVVP wires are designated for connection with white goods, electric soldering irons, lamps and other devices, operating in accommodation rooms.

Wires are designated for manufacturing of cord extension sets.

 

Construction

Conductors
Multicore copper round stranded conductors (class 5 in accordance with GOST 22483-77).

Insulation
Insulation is made from polyvinylchloride (PVC) compound.

Oversheath
Oversheath is made from polyvinylchloride (PVC) compound.

Technical characteristics

Wire Number of conductors Nominal conductors cross-section, mm
SHVVP 2, 3 0.5 – 6.0
PVS 2, 3, 4, 5 0.5 – 10

Electric resistance of conductors to DC calculated for 1 km at 20 C complies with GOST 22483.

Wires endure AC 2.0 kV 50 Hz test during 5 minutes.

Wires and cores with conductor cross-section area 4 mm and above must resist to repetitive bends through a system of rollers under current loading and endure at least 30000 bend cycles.

Nominal diameter of rollers and nominal tensile force:

Wire Nominal conductors cross-section, mm Nominal tensile force, H Nominal diameter of rollers, mm
SHVVP for any cross – sections 9.8 60
PVS 0.5 – 1.0 9.8 80
1.5 – 2.5 14.7 120
4.0 19.6 200

Wires and cores with conductor cross-section area 6 mm and above must resist repetitive π/2 radian bends at min. 49 H tensile force.

  • Nominal diameter of rollers – 200 mm.
  • Number of alternating bending - min. 9000.

Wires and cores are flame retardant with a single laying.

Protractedly permissible temperature for the conductors heating: min. 70 C.

Manufactured wire length: min. 100 m. Wires of variable lengths can be delivered upon request.

Guarantee period: 2 years from the commissioning date.

The manufacturer can ensure compliance of cable quality with requirements of current technical specification, provided all terms of transportation, storage, installation and use have been observed.

Service life: min. 10 years.

All products are certified.


Technical Data (reference values)

Number and nominal conductors cross-section, mm Max. overall diameter, mm Weight of 1 km cable, kg
Minimal Maximal
PVS
2×0.5 5.3 6.8 47
2×0.75 5.7 7.2 54
2×1.0 5.9 7.5 63
2×1.5 6.8 8.6 83
2×2.5 8.4 10.6 130
2×4.0 9.7 12.5 180
2×6.0 11.3 14.1 251
2×10 15.2 17.8 424
3×0.5 5.7 7.2 63
3×0.75 6.0 7.6 75
3×1.0 6.3 8.0 89
3×1.5 7.4 9.4 123
3×2.5 9.2 11.4 194
3×4.0 10.7 13.5 281
3×6.0 12.0 14.8 379
3×10 16.6 19.8 690
4×0.5 6.2 7.8 65
4×0.75 6.6 8.3 77
4×1.0 7.1 9.0 95
4×1.5 8.4 10.5 129
4×2.5 10.1 12.5 197
4×4.0 11.8 14.6 283
4×6.0 13.2 16.0 385
4×10 18.3 21.1 675
5×0.5 7.0 8.7 80
5×0.75 7.4 9.3 94
5×1.0 7.8 9.8 112
5×1.5 9.3 11.6 158
5×2.5 11.2 13.9 240
5×4.0 13.0 14.8 341
5×6.0 15.2 18.0 496
5×10 20.3 23.1 833
SHVVP
2×0.5 3.0×4.9 3.7×5.9 27
2×0.75 3.2×5.2 3.8×6.3 32
2×1.0 4.0×6.3 4.8×7.5 47
2×1.5 4.2×6.8 5.2×8.3 57
2×2.5 4.6×7.6 5.4×8.8 81
2×4.0 5.7×9.5 6.5×10.7 123
2×6.0 6.3×10.7 7.1×11.9 169
3×0.5 3.0×6.8 3.7×8.2 40
3×0.75 3.2×7.2 3.8×8.7 47
3×1.0 4.0×8.8 4.8×10.5 69
3×1.5 4.2×9.5 5.2×10.7 84
3×2.5 4.6×10.8 5.4×12.5 119
3×4.0 5.7×13.3 6.5×15.0 182
3×6.0 6.3×15.1 7.1×16.8 251

©