Wires and cores

Wires and cores

Wires and cables for rolling stock and railway transport 0.66 kV, 1.5 kV, 3 kV, 4 kV

PPSVVM, PPSVVM-1, KPSVVVM
(, -1, )
0.66 kV, 1.5 kV, 3 kV, 4 kV


Wires and cables for rolling stock and railway transport are designated for inner and outer connection of electric equipment of all types of railway and electric transport.

PPSVVM, KPSVVVM cables are designated for fixed installations and limited mobility assemblies with exposure to lubricating oils and diesel fuel with voltage 660 V, 1500 V, 3000 V or 4000 V AC at 400 Hz.

PPSVVM-1 cables are designed for steady installations at ambient temperature from -50 C up to +60 C.

Copper flexible non-insulated wires

G, GE
(, )

Copper flexible non-insulated wires are designated for electrical installations and devices (MG wires), and electrically heated furnaces (MGE wires) ranging of temperatures from -60 C up to +55 C and relative humidity up to 98 % at temperature up to (35±2) C.

Wire MG is copper flexible non-insulated wire.

Wire MGE is copper flexible non-insulated wire with flexible fiberglass yarn cable core.


Wires with PVC insulation for electric devices 0.45/0.75 kV

APV, PV1, PV3, PV4, PPV, APPV
(, 1, 3, 4, , )
0.45/0.75 kV

Wires are designated for electric appliances at stationary laying in lighting and power networks, for installations of electric machinery and appliance at nominal voltage up to 450 V (450/750 V) for networks with frequency up to 400 HZ or at DC voltage up to 1000 V.

APPV, PPV wires are laid in fixed installations.

APV, PV1 wires are laid in steel pipes, void channels of building constructions, electric circuit installation etc.

PV3 wires are laid in steel pipes, void channels of building constructions, electric circuit installations, etc. with exposure to frequent bending.

PV4 wires used in part of electric circuit installations with exposure to frequent bending.

Connecting wires and cores

PVS, SHVVP (, ) 380 V

Connecting wires and cores are designated for connecting with electric appliances and white goods for power network at nominal AC voltage up to 380 V of 380/660 V systems at ambient temperature from -40 C to +40 C.

PVS wires are designated for connection for white goods, electric soldering irons, lamps, etc. Wires are also designated for manufacturing of cord extension sets.

SHVVP wires are designated for connection with white goods, electric soldering irons, lamps and other devices, operating in accommodation rooms.

Wires are designated for manufacturing of cord extension sets.



©
2003–2021 CJSC Production Association Berdyansk Cable Plant
71101, Ukraine, Zaporozhye region,
Berdyansk, Promyshlennaya St., 2b
Phone: +380-6153-20000 (reception)
Made by 
Phantom, 2012